| 研究生: |
林柏宏 lin, Po-Hung |
|---|---|
| 論文名稱: |
應用適應性控制於主動式電力濾波器之研究 Study of Active Power Filter with Adaptive Control |
| 指導教授: |
李嘉猷
Lee, Jia-You |
| 學位類別: |
碩士 Master |
| 系所名稱: |
電機資訊學院 - 電機工程學系 Department of Electrical Engineering |
| 論文出版年: | 2002 |
| 畢業學年度: | 90 |
| 語文別: | 中文 |
| 論文頁數: | 111 |
| 中文關鍵詞: | 諧波 、適應性控制 、主動式電力濾波器 |
| 外文關鍵詞: | adaptive control, active power filter, harmonic |
| 相關次數: | 點閱:113 下載:5 |
| 分享至: |
| 查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
近年來,電力電子裝置產生之電力諧波所引起電力劣化的問題己漸受重視。因此,本論文主要針對諧波改善提出解決方法。其論文內容主要有兩個部份,第一個部份是在系統中加入一並聯型主動式電力濾波器,其功能是透過偵測設備得到非線性負載之諧波大小及相角,再由主動式濾波器產生一大小相同及相角相反之諧波組合,以抵消非線性負載產生之諧波。但通常在追補償電流的效果會因訊號延遲等現象而影響效果,所以本論文在第二個部份中即是加入適應性控制法則來解決上述問題。這樣一來即可獲得更正確的補償電流,使之可以提升諧波消除的效果。
Recently, the problem of power quality aggravation caused by power harmonic produced because of power electronic equipments has been concerned. So this thesis is mainly focused on the improvement of harmonic problem to propose solution. The content in the thesis has two parts: the first is to add a parallel active power filter in system, whose function is to get the same scale and phase of nonlinear load through sensing equipment and then product the combination of the same scale but opposite phase by active filter to cancel the harmonic caused by nonlinear load. Because the phenomenon of signal delay will affect the result of tracking compensated current, in the second part of this thesis it also adds the adaptive control method to solve the above-mentioned problem. In this way it can get more correctly compensated current to improve the effect of harmonic cancellation.
[1] L. Gyugyi and E. Strycula. “Active ac power filters,” IEEE/IAS Ann. Meeting, pp. 529, 1976.
[2] C. G. Ha and P. M. Ho, “Analysis and control of active power filter with optimized injection,” IEEE Trans. Power Electron., vol. 4, no. 4, pp. 57-65, 1996.
[3] Z. Li, H. Jin, and G. Joos, “Control of active filters using digital signal processors, in Proc. of IEEE IECON, vol. 1, no. 1, pp. 651 -655, 2000.
[4] H. Fujita and H. Akagi, “The unified power quality conditioner: The integration of series active filters and shunt active filters,” in Proc. of PESC '96, pp. 494 -501, 1996.
[5] S. Fukuda and T. Endoh, “Control method for a combined active filter system employing a current source converter and a high pass filter,” IEEE Trans. Industry Application, vol. 31, no.3, pp. 590 -597, 1995.
[6] 李昆岱, “應用DSP 實現重覆控制於具非線性負載變流器之研究”,國立成功大學電機工程研究所碩士論文,中華民國90 年。
[7] 陳本盛, “三相四線式主動電力濾波器” ,國立台灣大學電機工程學研究所碩士論文,中華民國89年。
[8] Y. Hayashi, N. Sato, and K. Takahashi , “A novel control of a current-source active filter for AC power system harmonic compensation,” IEEE Trans. Industry Application, vol. 27, no. 2, pp. 380-384, 1991.
[9] L. A. Moran, J. W. Dixon, and R. R. Wallace, “A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation,” IEEE Trans. Industry Electron., vol. 42, no. 4, pp. 402-408, 1995.
[10] L. T. Nam, et. al., “ Active damping of resonances in power systems,” IEEE Trans. Power Delivery, vol. 9, no. 2, pp. 1001 -1008, 1995.
[11] P. Mehta, M. Darwish, and T. Thomson “Switched-capacitor filters,” IEEE Trans. Power Electron., vol. 5, no. 3, pp. 331 -336, 1990.
[12] A. Cavallini and G. C. Montanari, “Compensation strategies for shunt active-filter control,” IEEE Trans. Power Electron., vol. 9, no. 6, pp. 587 -593, 1994.
[13] F. Z. Peng, “Application issues of active power filters,” IEEE Industry Applications Magazine, vol. 4, no. 5, pp. 21-30, 1998.
[14] H. Akagi, “New trends in active filters for power conditioning,” IEEE Trans. Industry Application, vol. 32, no. 6, pp. 1312-1322, 1996.
[15] M. E. Habrouk, M. K. Darwish, and P. Mehta, “Active power filters: a review,” IEE Trans. Electr. Power Applications, vol. 147, no. 5, pp. 403-413, 2000.
[16] B. Singh, K. A. Haddad, and A. Chandra, “A universal active power filter for single-phase reactive power and harmonic compensation,” Power Quality '98, pp.81-87, 1998.
[17] B. Singh, A. Chandra, and K. A. Haddad, “An improved single phase active power filter with optimum DC capacitor,” Proc. of IEEE IECON , vol. 2, pp. 677-682, 1996.
[18] D. Casadei, et. al., “Control methods for active power filters with minimum measurement requirements,” Proc of APEC '99, vol. 2, pp. 1153 -1158, 1999.
[19] C. Y Hsu and H. Y. Wu, “A new single phase active power filter with reduced energy storage capacity,” IEE Proc. Electr. Power Appl., vol. 143, no. 1, pp. 25-30, 1996.
[20] V. B. Bhavaraju and P. Enjeti, “A fast active power filter to correct line voltage sags,” IEEE Trans. Industry Electronics, vol 41, no. 3, pp. 333 -338, 1994.
[21] J. Nastran, et. al., “Active power filter for nonlinear AC loads,” IEEE Trans. Power Electron., vol. 9, no.1, pp. 92 -96, 1994.
[22] F. Z. Peng, H. Akagi, and A. Nabae, “Compensation characteristics of the combined system of shunt passive and series active filters,” IEEE Trans. Industry Application, vol.29, no.1, pp. 144 -152, 1993.
[23] H. Fujita and H. Akagi, “A practical approach to harmonic compensation in power systems-series connection of passive and active filters,” IEEE Trans. Industry Application, vol. 27, no.6, pp. 1020 -1025, 1991.
[24] F. Z. Peng, H. Akagi, and A. Nabae, “A new approach to harmonic compensation in power systems-a combined system of shunt passive and series active filters,” IEEE Trans. Industry Application, vol. 26, no. 6, pp. 983 -990, 1990.
[25] L. Moran, et. al., “Series active power filter compensates current harmonics and voltage unbalance simultaneously,” Generation, Transmission and Distribution, IEE Proc., vol. 147, no. 1, pp. 31-36, 2000.
[26] S. Bhattacharya, P. T. Cheng, and D. M. Divan, “Hybrid solutions for improving passive filter performance in high power applications,” IEEE Trans. Industry Application, vol. 33, no.3, pp. 732 -747, 1997.
[27] M. Rastogi, N. Mohan, and A. A. Edris, “Hybrid-active filtering of harmonic currents in power systems,” IEEE Trans. Power Delivery, vol. 10, no.4, pp. 1994 -2000, 1995.
[28] N. Balbo, et. al., “Hybrid active filter for parallel harmonic compensation,” Power Electron. and Applications, 8., Fifth European Conf. , 1993.
[29] 吳晉昌, “新型虛功補償及諧波抑制之主動電力濾波器” ,國立成功大學電機所碩士論文, 中華民國81年。
[30] 岡村迪夫著,陳連春譯,運算放大器應用鐵則。建興,1995。
[31] A. V. Oppenheim, E. Weinstein, K. C. Zangi, M. F., and D. Gauger, “Single-sensor Active Noise Cancellation,” IEEE Trans. Speech and Audio Processing., vol. 2, no. 2, pp.285-290, 1994.
[32] B. Widrow and S. D. Stearns, Adaptive Signal Processing, Prentice Hall, 1985.
[33] F. Fukuda and S. Sugawa, “Adaptive signal processing based control of active power filters,” IAS '96 Recod., vol. 2, pp. 886-890, 1996.
[34] S. Luo and Z. Hou, “An adaptive detecting method for harmonic and reactive currents,” IEEE Trans. Industry Electron., vol. 42, no. 1, pp.85-89, 1995.
[35] S. Haykin, “Introduction to adaptive filters”, Macmillan publishing Company, New York, USA.1984.
[36] H. W. Ott, Noise Reduction Techniques in Electronic System, John Wiley & Sons, New York, 1988.
[37] TMS320C 1x/C2x/C2xx/C5x Assembly Language Tools, Texas Instruments, 1995.
[38] TMS320C24x C Source Debugger User's Guide, Texas Instruments, 1995.
[39] TMS320C24x DSP Controllers CPU, System, and Instruction Set, vol. 1, Texas Instruments, 1997.
[40] TMS320C24x DSP Controllers peripheral Library and Specific Devices , vol. 2, Texas Instruments, 1997.