心血管系統為人類維持生命的重要循環系統之一,如何檢測它們是否處於健康狀態是一個很重要的課題。目前市面上充斥著各式各樣的生理監測系統,大部份使用的是有線錄製系統,並將資料存放於多媒體儲存裝置內。本論文將結合無線傳輸系統,開發出一套可以輕易裝設及卸下之無線腕式生理記錄器,用來記錄人體血氧濃度和心率變化。此外,記錄器內部另有裝設加速規記錄手部動作,可用來去除手部動作雜訊造成的血氧量測誤判,同時也可以做為日常生活的活動量記錄器。此記錄器提供了輕便的生理訊號記錄功能,由於系統為多個模組整合而成,未來可使用新的演算法和新的感測器做出一套新的系統來。
The cardiovascular system is an important circulatory system for human, it is a big issue to diagnose whether people are healthy or not; there are many kinds of physiological monitoring devices on the market, most of them are wired system and stored on the multimedia storage device.
In this thesis, the system is designed in a wireless transmission module, and developed a real-time signal monitoring system. The wireless wrist physiological monitoring device records the signals, such as SpO2, heart rate, and tri-axis accelerometer. The accelerometer is used for bypassing the moving artifact; it is used for recording the actigraphy as an acti-watch.
The device is an easy-to-use recording system; it is integrated by modules, and can be modified into another recording system using the new sensors or algorithms.
Advanced Medical Equipment Ltd., "Siesta 802 User Guide". Available: http://www.advancedmedicalequipment.com/Index.html, 2004.
Allen J., "Photoplethysmography and its application in clinical physiological measurement," Physiological measurement, vol. 28, p. R1, 2007.
Aminian K., Robert P., Buchser E., Rutschmann B., Hayoz D., and Depairon M., "Physical activity monitoring based on accelerometry: validation and comparison with video observation," Medical and Biological Engineering and Computing, vol. 37, pp. 304-308, 1999.
Analog Device, Inc., "ADXL335 Datasheet". Available: http://www.analog.com/en/index.html, 2009.
Bindra D. S., Zhang Y., Wilson G. S., Sternberg R., Thevenot D. R., Moatti D., and Reach G., "Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring," Analytical chemistry, vol. 63, pp. 1692-1696, 1991.
Covidien, "OxiMax Durasensor® DS-100A". Available: http://respiratorysolutions.covidien.com/Home/tabid/38/Default.aspx, 2011.
Feissel M., Kalakhy R., Badie J., Robles G., Faller J., and Teboul J., "Plethysmography variability index: a new fluid responsiveness parameter," Critical Care, vol. 13, p. P205, 2009.
Fitbit, Inc., "Wireless Activity Tracker". Available: http://www.fitbit.com/, 2011.
Jubran A., "Pulse oximetry," Applied Physiology in Intensive Care Medicine, pp. 45-48, 2009.
Karantonis D. M., Narayanan M. R., Mathie M., Lovell N. H., and Celler B. G., "Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring," Information Technology in Biomedicine, IEEE Transactions on, vol. 10, pp. 156-167, 2006.
Kastle S., Noller F., Falk S., Bukta A., Mayer E., and Miller D., "A new family of sensors for pulse oximetry," HEWLETT PACKARD JOURNAL, vol. 48, pp. 39-47, 1997.
Lai C., Huang Y. M., Chao H. C., and Park J. H., "Adaptive body posture analysis using collaborative multi-sensors for elderly falling detection," IEEE Intelligent Systems, 2010.
Lewicke A., Sazonov E., Corwin M. J., Neuman M., and Schuckers S., "Sleep versus wake classification from heart rate variability using computational intelligence: consideration of rejection in classification models," Biomedical Engineering, IEEE Transactions on, vol. 55, pp. 108-118, 2008.
Lichstein K. L., Stone K. C., Donaldson J., Nau S. D., Soeffing J. P., Murray D., Lester K. W., and Aguillard R. N., "Actigraphy validation with insomnia," Sleep, vol. 29, pp. 232-239, 2006.
Liu Y. C., "An Adaptive Actigraphy Analysis Method for Sleep-Wake Identification," National Cheng Kung University, Tainan, 2010.
Lyons G., Culhane K., Hilton D., Grace P., and Lyons D., "A description of an accelerometer-based mobility monitoring technique," Medical engineering & physics, vol. 27, pp. 497-504, 2005.
Matviyenko S., "Pulse Oximeter," 2005.
National Semiconductor, "LM1117 Series Low Dropout Voltage Regulators". 2004.
Nieto F. J., Young T. B., Lind B. K., Shahar E., Samet J. M., Redline S., D'Agostino R. B., Newman A. B., Lebowitz M. D., and Pickering T. G., "Association of sleep-disordered breathing, sleep apnea, and hypertension in a large community-based study," JAMA: the journal of the American Medical Association, vol. 283, p. 1829, 2000.
Nikooie R., Gharakhanlo R., Rajabi H., Bahraminegad M., and Ghafari A., "Noninvasive Determination of Anaerobic Threshold by Monitoring the% SpO2 Changes and Respiratory Gas Exchange," The Journal of Strength & Conditioning Research, vol. 23, p. 2107, 2009.
Nonin Medical Inc., "Pulse Oximetry". Available: http://www.turnermedical.com/, 2011.
Philips, "Actiwatch Family of Ambulatory Actigraphy Devices". Available: http://www.actiwatch.respironics.com/default.asp, 2011.
Reynolds K. J., Palayiwa E., Moyle J. T. B., Sykes M. K., and Hahn C. E. W., "The effect of dyshemoglobins on pulse oximetry: Part I, Theoretical approach and Part II, Experimental results using an in vitro test system," Journal of clinical monitoring and computing, vol. 9, pp. 81-90, 1993.
Rusch T., Sankar R., and Scharf J., "Signal processing methods for pulse oximetry* 1," Computers in biology and medicine, vol. 26, pp. 143-159, 1996.
Schmitt P. M., Gobel T., and Trautvetter E., "Evaluation of pulse oximetry as a monitoring method in avian anesthesia," Journal of Avian Medicine and Surgery, pp. 91-99, 1998.
Slavi ek J., Kittnar O., Fraser G. E., Medova E., Kone na J., i ka R., Dohnalova A., and Novak V., "Lifestyle decreases risk factors for cardiovascular diseases," Central European journal of public health, vol. 16, p. 161, 2008.
Texas Instruments, "CC2430 Datasheet". Available: http://www.ti.com, 2010.
Veltink P. H., Bussmann H. B., de Vries W., Martens W. L., and Van Lummel R. C., "Detection of static and dynamic activities using uniaxial accelerometers," Rehabilitation Engineering, IEEE Transactions on, vol. 4, pp. 375-385, 1996.
Wang L., Wei W., Gong M., and Mu L., "A comparison of response time to desaturation between tracheal oximetry and peripheral oximetry," Journal of clinical monitoring and computing, vol. 24, pp. 149-153, 2010.
Zmode Technology Co., Ltd, "TI CC2430 Module". Available: http://www.zmode.com.tw/, 2007.
台美國際有限公司, "各式血氧感測器系統". Available: http://www.eddmed.com.tw/, 1997.