| 研究生: |
莊政陽 Zhnang, Zheng-Yang |
|---|---|
| 論文名稱: |
快速動眼期量測與睡眠品質評估系統之初探 A Preliminary Study of Rapid-Eye Movements Measurement And Sleep Quality Evaluation System |
| 指導教授: |
楊明興
Young, M.S. |
| 學位類別: |
碩士 Master |
| 系所名稱: |
電機資訊學院 - 電機工程學系 Department of Electrical Engineering |
| 論文出版年: | 2006 |
| 畢業學年度: | 94 |
| 語文別: | 中文 |
| 論文頁數: | 42 |
| 中文關鍵詞: | 快速動眼期(REM)、資料擷取卡(USB-6009)、LabVIEW |
| 外文關鍵詞: | USB-6009, REM, LabVIEW |
| 相關次數: | 點閱:86 下載:4 |
| 分享至: |
| 查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
在現今繁忙的社會有許多的壓力,造成人們晚上睡眠的困擾,也可能影響個人健康,進而使得工作效率降低及醫療資源的浪費,所以近年來睡眠問題逐漸受到大家的重視。因此設計一套簡單且有效的睡眠評估系統,為醫生和研究人員提供一個初步的參考或供人們居家使用,也就成為一個重要的課題。
本研究以快速動眼期信號為量測對象,並將其量測模組化,由所設計的硬體系統將量測到的快速動眼信號經USB-6009資料擷取卡傳到電腦顯示與儲存,最後再透過 LabVIEW 軟體所撰寫的程式來探討睡眠與快速動眼期的關聯性。
In the busy society, a lot of pressures may induce people's sleep-disorder, which may in turn influence the personal health, decrease working efficiency reduce and consume much more medical resource. Gradually, the sleep-disorder has been the focus that everybody paid attention to. So, it is important to design one kind of simple and effective sleep evaluation system to offer the doctor or researcher a primary data or provide people to use at home.
In this thesis, we adopt the signals of Rapid-Eye Movements as measurand, and measure them by a self-designed modularized hardware. Then the measured REM signals are sent through an USB-6009 type data acquisition card to personal computer for displaying and storage. Finally,
we study the relationship between sleep and Rapid-Eye Movements by analyzing the acquired data with LabVIEW-based graphical program.
[1] 眼電圖法(Electro-Oculography, EOG)
http://cslin.auto.fcu.edu.tw/bioassist/bioassist/inte/2/1-05.htm
[2] 劉勝義,臨床睡眠檢查學,民國93年,合記圖書出版社
[3] Tomoka Takeuchi, Suzie Laroche, and Jean Gotman Rajeev Agarwal*,, “Detection of Rapid-Eye Movements in Sleep Studies” Member, IEEE TRANS. ON BIOMEDICAL ENGINEERING, August 2005.
[4] Medical Electronics Laboratory,Basic Theory of Bio-
amplifiers,Tampere University of Technology.
[5] INA155 COMS INSTRUMENTATION AMPLIFIER
[6] CR2032 Manganese Dioxide Lithium Coin Batteries
[7] USER GUIDE AND SPECIFICATIONS NI USB-6008/6009
[8] G.M. Hatzilabrou, N. Greenberg, R. J. Schlabassi, T. Carroll, R. D. Guthrie, and M. S. Scher, “A comparison of conventional and matched filtering techniques for rapid eye movement detection of the newborn,” IEEE Trans, Biomed,Oct,1994
[9] J. Doman, C. Detka, T. Hoffman, D. Kesicki, J. P. Monahan, D. J.Buysse, C. F. Reynolds 3rd, P. A. Coble, J. Matzzie, and D. J. Kupfer,“Automating the sleep laboratory: implementation and validation ofdigital recording and analysis,” Int. J. Biomed. Comput., vol. 38, pp.277–290, 1995.
[10] C. Smith and L. Lapp, “Increases in number of REMS and REM densityin humans following an intensive learning period,” Sleep, vol. 14, pp.325–330, 1991.
[11] 張凱雄,”嵌入式心電圖量測系統設計及其在遠距個人保健上
之應用”,國立成功大學電機研究所碩士論文,2004。
[12] Texas Instrument,Analysis of the Sallen-Key Architect-
ure,TI,1999。
[13] 楊勝嚴,”人體末梢血流量波形之量測、分析與應用”,國立成功大學電機研究所 碩士論文,2002。
[14]http://www.itri.org.tw/chi/services/ieknews/h2001-B01-30036-8B6F-0.PDF
[15]http://cslin.auto.fcu.edu.tw/bioassist/bioassist/inte/2/1-05.htm
[16] 謝勝治,圖控程式語言LabVIEW,全華科技圖書股份有限公司,臺北市,2003 。
[17] 周靜娟、吳明瑞、顏培仁,圖控程式語言LabVIEW,全華科技圖書股份有限公司,臺 北市,2005 。
[18] 睡眠多項生理檢查儀 作者:阮致維(2005-04-01)
[19]台灣醫學會http://formosan.mc.ntu.edu.tw/medicial_data/taiwan03.htm