| 研究生: |
林佳靜 Lin, Jia-Jing |
|---|---|
| 論文名稱: |
模擬血管阻塞對脈搏波速影響的實驗研究 Experimental Study of the Modeling Blood Vessel Corrugation Effects on Pulsed Wave Velocity |
| 指導教授: |
尤芳忞
Yu, Fan-Ming |
| 學位類別: |
碩士 Master |
| 系所名稱: |
工學院 - 航空太空工程學系 Department of Aeronautics & Astronautics |
| 論文出版年: | 2008 |
| 畢業學年度: | 96 |
| 語文別: | 中文 |
| 論文頁數: | 58 |
| 中文關鍵詞: | 頻譜分析 、脈波波速 、血管阻塞 |
| 外文關鍵詞: | pulse wave velocity, blood vessel corrugation, spectral analysis |
| 相關次數: | 點閱:100 下載:1 |
| 分享至: |
| 查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
本實驗研究的目的在於探討模擬血管阻塞與脈搏波速間之關係,其中使用兩個微型麥克風分別安置於模擬血管的上游與下游以建立一個便利的測量脈搏波速的技術。本研究利用橡膠管和填充阻塞物的橡膠管來模擬血管阻塞情形,由麥克風感測器以測量橡膠管波動,分析訊號後可得到脈波波速及頻譜分析的變化。實驗結果顯示,有阻塞物的模擬血管脈波波速減小,經頻譜分析比較,模擬血管阻塞後的主頻位置沒有顯著更動但整體共振頻率振幅會增加。實驗結果也顯示可利用時間頻率分析圖來討論血管阻塞與否時的差異特質,以供未來分析人體血管阻塞時的應用。
The investigation on the modeling of the blood vessel corrugation effects on the pulsed wave velocity has been done in the Fluid Mechanics Laboratory of National Cheng Kung University. By using two microphones to build up a convenient tool for measuring the pulse wave velocity in the modeling blood vessel. The modeling of blood vessel blocking was done by using the rubber tubes and obstruction inside it. The acoustic signal obtained by the microphones were used to calculate the variation of the pulse wave velocity as well as for the spectral analysis. The results show that the pulsed wave velocity of the blocking model blood vessel is slower. In these cases , the primary frequency positions do not change much, but the oscillation amplitude of them have been increased as show in the spectral diagrams. The experimental results also indicate that the temporal to frequency analysis results is a proper tool to analyse the pulse wave date. Which is suitable for rhe analysis on human body by using a pair of acoustic transducers.
[1] Milnor, W.R., Hemodynamics, 2nd edition, Batimore, Maryland, Williams & Wlikins Co., 1989
[2] Wilmer, W. Nichols and Michael F. O’Rourke, McDonald’s Blood Flow in Arteries, 3rd edition, Philadelphia, London, 1990.
[3] Crighton Bramwell , J. and Hill, A.V. “The Velocity of the Pulse Wave in Man,” Proceedings of the Royal Society of London. Series B, Containing Paper of a Biological Character 93: 298-306, 1922.
[4] Bergel, D. H., “The dynamic elastic properties of the arterial wall,” The Journal of Physiology 156: 458-469, 1961
[5] Womersley, J. R., “Oscillatory flow in arteries: The constrained elastic tube as a model of arterial flow and pulse transmission.” Physics in Medicine and Biology 2: 178-187, 1957.
[6] Womersley, J. R., “Oscillatory flow in arteries: The reflection of the pulse wave at junctions and rigid inserts in the arterial system.” Physics in Medicine and Biology 2: 313-323, 1958
[7] Milnor, W. R., Bergel, D. H., and Bargainer, J. D., “Hydraulic power associated with pulmonary blood flow and its relation to heart rate.” Circulation Research 19: 467-480, 1966.
[8] Milnor, W. R., Conti, C. R., Lewis, K. B., and O’Rourke, M. F., “Pulmonary arterial pulse wave velocity and impedance in man.” Circulation Research 19: 637-349, 1969.
[9] 王唯工,氣的樂章,第二章,大塊文化出版社,2002.
[10] Pruett, J. D., Bourland, J. D., Geddes, L. A., “Measurement of Pulse-wave velocity using a beat-sampling technique.” Annals of Biomedical Engineering, Vol. 16, pp. 341-347, 1988.
[11] Marque,Valerie , Van Essen, Helma , Harry, Struijker-Boudier, A. J., Atkinson,Jeffrey , Lartaud-Idjouadiene, Isabelle, “Determination of aortic elastic modulus by pulse wave velocity and wall tracking in a rat model of aortic stiffness.” Journal Vascular Research 38: 546-550, 2001.
[12] Jadhav ,Uday M., Kadam, N.N., “Non-invasive assessment of arterial stiffness by pulse wave velocity correlates with endothelial dysfunction.” Indian Heart Journal 57: 226-232, 2005.
[13] Harada,Akimitsu , Okada,Takashi , Niki,Kiyomi , Chang,Dehua , Sugawara,Motoaki , “On-line noninvasive one-point measurements of pulse wave velocity.” Heart Vessels 17: 61-68, 2002.
[14] Chlup,Hynek, Mackova,Hana , Vilimek,Miloslav , Kubovy,Petr , Zitny,Rudolf , Konvickov,Svatava , “Pulse wave velocity in elastic tube,” Modelling, Identification, and Control, February 6-8, Lanzarote, Canary Islands, Spain, 2006.
[15] 蔡昇育,“血管橈度與脈搏波速間關係之實驗模擬研究”,國立成功大學航太所碩士論文,2007.
[16] Aperia, A., “ Hemodynamical studies. ” Scan Arch Physiol , 1940.
[17] Akselrod,Solange ,Gorden,David, Ubel,F.Andrew, Shannon,Daniel C. Barger,A.Clifford, Cohen, Richard J., “ Power Spectrum Analysis of Heart Rate Fluctuation : A Quantitative Probe of Beat-to-Beat Cardiovascular Control. ” Science Vol.213, 10 July, 1981.
[18] Daniels, F.H., Keibard, E.F., Cortell, S., “Spectral analysis of arterial blood pressure in the rat.” IEEE Transaction on biomedical Engineering, 1983.
[19] Lee, C.T., Wei, L.Y., “Spectrum analysis of human pulse. ” IEEE Transaction on biomedical Engineering, 1983.
[20] Chen,Jian-jung , “Application of the Principle pulse Diagnostics in Chinese Medicine and Measured Pulse Wave Signal to Clinical Diagnoses, ” Yearbook of Chinese Medicine and Pharmacy, 25(5), 211-262 , 2007.
[21] Hlimonenko,Irina ,Meigas,Kalju ,Vahisalu,Rein ,“Waveform analysis of peripheral pulse wave detected in the fingertip with photoplethysmograph.” Measurement Science Review, Vol. 3 Sec. 2, 2003.
[22] O’Rouke, M.F. “The arterial pulse in health and disease. ” Am Heart J, Nov;82(5):687-702 ,1971.
[23] O’Rouke, M.F. “Effects of majuor occlusion on the pressure wave transmission along the human aorta.” Proc Aust Physiolsoc, p24, 1969.