荖濃溪位於台灣南部,為高屏溪的主流上游。目前六龜區當地居民所使用之水源,主要由六龜淨水廠所提供之自來水以及部分山泉水,而六龜淨水廠之原水,是藉由寬口井取用荖濃溪河川水。因六號井為現僅存在唯一可以取水之寬口井,一旦遇到颱洪期河床原水濁度飆升時,因濾層無法滲濾高濁度河床原水,而導致六龜淨水廠無法取水使用,造成當地居民無水可用。所以現階段要改善此問題,必須先解決六號井因濁度飆升,無法正常供水之困難。
之前已做過一~六號井,但是無法正常供水,現增加七號井來改良之前的取水功能。七號井布置主要原則為:(1)由濾層來增加透水系數;(2)洪水通過時破壞濾層,不影響取水;(3)利用筐網群保護濾層及造成主深槽取水;(4)利用豎立透水柱,來增加透水量;(5)由集水井來增加取水的速率。
六號井為傳統的管路取水,而七號井為濾層改良取水,經由平時及洪水期間,比較六號井及七號井取水功能,在平時期間六號井的濁度由49NTU下降至48NTU;七號井的濁度由24NTU下降至1.5NTU,在洪水期間六號井的濁度由250NTU下降至248NTU;七號井的濁度由250NTU下降至15NTU。
由上得知,七號井的濾層改良,可達到降低濁度的效果,及洪水期間可以取到濁度較小的原水,可由自來水公司直接處理,而改進洪水期間仍然可以供水。
Laonong River located in southern Taiwan is an upstream of the main branch of Kaoping River. Currently the water that Liouguei District residents use is mainly provided by the Liouguei clean water facility and some mountain spring water. The water that the Liouguie clean water facility uses is drawn from a large well supplied by the Laonong River. During the flood season, water turbidity in Laonong River increases exponentially and cannot be adequately filtered to provide clean water to the residents at the Liouguei District. Therefore, water turbidity in well NO.6 should be first addressed to prevent disruption of water supply during the flood season.
The proposed solution is to develop well NO.7 which will have the following features: (1) Increasing infiltration coefficient by adding additional water infiltration filters. (2) Protecting water during flood season. (3) Using mesh to protect infiltration filters and creating reservoir for water collection. (4) Increasing flooding volume using vertical permeable columns. (5) Increasing water collection rate using water reservoirs.
Well NO.6 uses the traditional water pipes to collect water, but well NO.7 uses filter walls. By comparing the performance of the two wells, data shows that in normal season, well NO.6 reduces turbidity from 49 NTU to 48 NTU versus well NO.7 reducing turbidity from 24 NTU to 1.5 NTU. During the flood season, well NO.6 reduces turbidity from 250 NTU to 248 NTU versus well NO.7 reducing turbidity from 250 NTU to 15 NTU. Date clearly demonstrates the higher performance of using filter walls to reduce water turbidity and can help ensure continuous water supply during the flood season.
1、中鼎工程公司,「高屏溪沿岸及隘寮溪中下游淺層地下水開發評估及備援系統規劃」,經濟部水利署南區水資源局開發計劃研究報告,2006。
2、中華民國自來水協會,「自來水工程設施標準解說」,中華民國自
來水協會,2006。
3、王國祥,「林邊溪上游二峰圳集水廊道工程技術與應用之研究」,
國立屏東科技大學土木工程系,碩士論文,2008。
4、石武融,「透水性筐網圓柱之流場試驗研究」,國立成功大學水利
及海洋工程學系,碩士論文,2007。
5、朱宏翊,「筐網群結構物對橋墩沖刷保護效果之研究」,國立成功
大學水利及海洋工程學系,碩士論文,2007。
6、黃怡仁,「直排筐網群樁於渠道中之沖淤現象」,國立成功大學水
利及海洋工程學系,碩士論文,2009。
7、陳勇銘,「高屏溪右岸高灘地伏流水評估研究」,國立屏東科技大
學土木工程系,碩士論文,2007。
8、許少華、倪春發,「濁水溪伏流水取水管設計原則之研究期末報
告」,經濟部水資源局,2000。
9、許少華、黃文圻、林時猷「以河底集流管開採河川伏流水量之評
估方法探討」,中國農業工程學報第四十八卷第一期,第39至51頁,2002年3月。
10、張振生,「哈盆溪上游集水區伏流水動態研究」,國立臺灣大學森林學研究所,博士論文, 2000。
11、張則安、李明熹、王志賢「高屏溪流域上游坡地莫拉克風災整體復建規劃」行政院農業委員會水土保持局臺南分局,初期簡報,
2009。
12、葛清富,「莫拉克颱風對六龜寬口井之衝擊及其改善策略」2011。
13、經濟部水利署水利規劃試驗所,「既設河道集水暗渠功能調查分
析及因應環境變遷所應考慮的設計原則-以中部地區為例」,經濟 部,政府科技計畫成果效益報告,2009。
14、簡新洋,「滲濾管集水量之初步試驗研究」,國立屏東科技大學土木工程系,碩士論文,2007。