| 研究生: |
張展榕 Chang, Chan-Rung |
|---|---|
| 論文名稱: |
火害後SM570等級H型鋼柱受軸壓與反覆側推行為之研究 The Post-Fire Lateral Cyclic Loading Behaviors of the Axial Loaded SM570 Grade H-Shaped Steel Columns |
| 指導教授: |
鍾興陽
Chung, Hsin-Yang |
| 學位類別: |
碩士 Master |
| 系所名稱: |
工學院 - 土木工程學系 Department of Civil Engineering |
| 論文出版年: | 2021 |
| 畢業學年度: | 109 |
| 語文別: | 中文 |
| 論文頁數: | 292 |
| 中文關鍵詞: | 火害後 、高性能鋼 、H型鋼柱 、反覆側推試驗 、耐震能力 |
| 外文關鍵詞: | Post Fire, High Performance Steel, H-Shaped Steel Column, Lateral Cyclic Loading Test, Seismic-Resistant Performance |
| 相關次數: | 點閱:225 下載:0 |
| 分享至: |
| 查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
本研究主要探討以SM570等級高性能鋼鋼材製成的BH型鋼柱試體於火害前與火害後之耐震性能差異,因此特別製作三組材質與尺寸皆相同的半柱試體,對三組試體進行不同溫度處理 (即:放置常溫下的對照組R2試體、經900℃高溫後自然冷卻的A9試體、經900℃高溫後水中冷卻的W9試體),研究SM570等級鋼柱於高溫火害前後的機械性質變化,另外針對三組試體將施加相同軸壓力並進行相同反覆側推歷程獲取數據,比對鋼柱試體於火害前後對其耐震能力影響,發現未受火害之R2試體與經900℃高溫後水中冷卻的W9試體符合美國耐震規範AISC 341-16之SMF梁柱接頭達到4%層間位移角和0.8Mp彎矩強度的規定經900℃高溫後自然冷卻的A9試體,因鋼材強度大幅減弱,不符合美國耐震規範AISC 341-16中SMF梁柱接頭的規定。
This study mainly investigated the pre-fire and post-fire seismic-resistance differences of the BH steel column specimens made of SM570 grade high performance steel. Therefore, three half-column specimens with the same material and dimensions were made. The three specimens were treated with three different temperature treatments respectively, and were named as R2, A9 and W9. R2 was the specimen without fire damage. A9 was the specimen heated to 900°C high temperature and then air-cooled to room temperature. W9 was the specimen heated to 900°C high temperature and then water-cooled to room temperature. The three specimens were subjected to the same axial compressive load and the same lateral cyclic loading protocol to obtain the pre-fire and post-fire seismic-resistance differences of the SM570 steel half-columns. Experiment results showed that the R2 specimen and the W9 specimen could reach the 4% interstory drift and 0.8Mp moment strength, and therefore met the the special moment frame (SMF) beam-to-column connection requirements in the AISC 341-16 seismic provisions. Due to the post-fire steel strength was decreased greatly, the A9 specimen did not meet the requirements of SMF beam-column connections in the AISC 341-16 seismic provisions.
Lee, C. H., Shin, H. S. and Park, K. T. , “Evaluation of high strength TMCP steel weld for use in cold regions,” Journal of Constructional Steel Research, Vol. 74, pp. 134-139, 2012.
Parthiban, R., Chowdhury, S. G., Harikumar, K. C. and Sankaran, S., “Evolution of microstructure and its influence on tensile properties in thermo-mechanically controlled processed (TMCP) quench and partition (Q & P) steel,” Materials Science & Engineering A, Vol. 705, pp. 376-384, 2017.
Jiang, J., Bao, W., Peng, Z. Y., Wang, Y. B., Liu, J. and Dai, X. H., “Experimental investigation on mechanical behaviours of TMCP high strength steel,” Construction and Building Materials, Vol. 200, pp. 664-680, 2019.
Chang, K. H., Jang, G. C., Park, C. M. and Gil, H. B., “Strain-rate dependence of mechanical behavior and hysteretic characteristics of TMCP steel (SM570-TMC) and its modeling,” Computational Materials Science, Vol. 45, pp. 669-673, 2009.
Chopra, A. K., Dynamics of structures: Theory and applications to earthquake engineering 4th ed. 2012:Prentice Hall
Hashmi, S., Comprehensive Materials Processing 1st Edition, 2014
Uang, C. H. and Newell, J., “Cyclic Behavior of Steel Columns with Combined High Axial Load and Drift Demand,” University of California, San Diego Department of Structural Engineering Structural Systems Research Project, Report No. SSRP-06/22, 2006.
AISC, Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction, Chicago, Illonois, 2016.
Chou, C. C. and Chen, G. W., “Lateral cyclic testing and backbone curve development of high-strength steel built-up box columns under axial compression,” Engineering Structures, Vol. 223, Available online, 2020
Phan, H. D., “Seismic Behavior of Full-Scale Concrete Filled Steel Tubular(CFST) Columns with High Axial Load Effect.,” Ph.D. Dissertation, National Taiwan University of Science and Technology, Taiwan, July (2020).
Liu, M., Fan, S., Ding, R., Chen, G., Du, E. and Wang, K., “Experimental Investigation on the Fire Resistance of Restrained Stainless Steel H-section Columns,” Journal of Constructional Steel Research, Vol. 163, Available online, 2019.
Ali, P. I., Afshan, S. and Foster, A. S. J., “Structural Fire Performance of Axially and Rotationally Restrained Stainless Seel Columns,” Thin-Walled Structures, Vol. 137, pp. 561-572, 2019.
Wang, W., Kodur, V., Yang, X. and Li, G., “Experimental Study on Local Buckling of Axially Compressed Steel Stub Columns at Elevated Temperatures,” Thin-Walled Structures, Vol. 82, pp. 33-45, 2014.
Li, G. Q. and Zhang, C., “Creep Effect on Buckling of Axially Restrained Steel Columns in Real Fires,” Journal of Constructional Steel Research, Vol. 71, pp. 182-188, 2012.
Wang, W. Y. and Li, G. Q., “Behavior of Steel Columns in a Fire with Partial Damage to Fire Protection,” Journal of constructional steel research, Vol.65(6), pp. 1392-1400, 2009.
中國鋼鐵(2014),型鋼目錄手冊。
潘吉齡、林新華、余志鵬與林政億,「高興能鋼材應用於建築之研究」,建築學報68期,pp.55-70,2009。
簡丞宏,「H型鋼柱高溫整體結構行為研究」,碩士論文,國立高雄第一科技大學營建工程所,2005。
李鴻欣,「H 型鋼柱高溫局部挫屈行為研究」,碩士論文,國立高雄第一科技大學營建工程所,2004。
林德宏、林克強與蔡克銓,「國震中心台南實驗室BATS系統」,年度成果報告,國家地震工程研究中心,2017。
林旺春、劉瓊林、楊卓諺、游忠翰、汪向榮與黃震興,「雙軸向動態試驗系統之基本參數研究與探討」,年度成果報告,國家地震工程研究中心,2018。
周民瑜,「常見結構用鋼材火害後機械性質之研究」,碩士論文,國立成功大學土木工程系,台南(2008)。
陳兆誼,「耐火剛與普通鋼及相關梁柱接頭銲道火害後反覆側推行為之研究」,碩士論文,國立成功大學土木工程系,台南(2013)。
潘韻瑋,「H型梁與箱型柱彎矩接頭於火害後反覆側推行為之精確數值模擬」,碩士論文,國立成功大學土木工程系,台南(2014)。
張嘉元,「火害後空氣冷卻H型梁-箱型柱彎矩接頭耐震行為之研究」,碩士論文,國立成功大學土木工程系,台南(2015)。
陳宥豪,「火害後水中冷卻H型梁-箱型柱彎矩接頭耐震行為之研究」,碩士論文,國立成功大學土木工程系,台南(2015)
賴傳詠,「火害後H 型梁-箱型柱彎矩接頭反覆載重試驗之數值模擬」,碩士論文,國立成功大學土木工程系,台南(2015)。
廖浩仁,「火害後耐火鋼圓弧切消減弱式梁柱彎矩街頭耐震行為之研究」,碩士論文,國立成功大學土木工程系,台南(2017)。
王順儒,「火害後耐火鋼側板補強式梁柱彎矩街頭耐震行為之研究」,碩士論文,國立成功大學土木工程系,台南(2017)。