論文名稱: 水平導風百葉開口部對室內自然通風效果影響之研究
A Study of the Influence of horizontal louvers on Natural Ventilation in a Dwelling Unit
指導教授: 江哲銘
Chiang, Che-Ming
學位類別: 碩士
Master
系所名稱: 規劃與設計學院 - 建築學系
Department of Architecture
論文出版年: 2003
畢業學年度: 91
語文別: 中文
論文頁數: 80
中文關鍵詞: 風擊不滿意度換氣量單側通風數值解析足尺實驗水平導風百葉
外文關鍵詞: DR, air flow rate, horizontal louvers, full-scale experiment, CFD, single-sided ventilation
相關次數: 點閱:159下載:10
分享至:
查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報
  • 本研究以居室空間單側通風模式為探討對象,針對水平導風百葉開口部對室內換氣效果之影響進行研究,希冀藉由水平導風百葉取代前期研究之中央橫軸旋轉窗,在兼顧室內換氣健康及人員舒適性之同時,亦不至於對空間利用造成不便性。運用CFD數值解析方式進行室內穩態氣流場、溫度場模擬,並配合足尺實驗方法檢證模擬之精確性,作為數值模擬邊界條件設定之修正。研究討論部分,先對室內有無人體發熱源進行換氣量分析,藉此瞭解熱浮力效應對居室空間單側通風模式之影響程度,確認本研究後續討論之變因設定。再分別探討不同水平導風百葉深度對換氣量、溫度累積分佈及風擊不滿意度等因子之影響關係,綜合上述健康性與舒適性之評估結果,找尋較佳之百葉深度範圍,並提出相關查核資料以供設計者參考。

    According to previous research, the central horizontal pivot window could contribute to the improvement of indoor air quality under single-sided ventilation. But for interior space using, it would be inconvenient. In the present study the horizontal pivot window would be replaced by horizontal louvers and the work was focused on what is a proper opening design, which could be used to promote natural ventilation, and keep users be comfortable. We tried to use numerical method to simulate ventilation performance of different louver’s depths as well as different wind speed. Air flow was considered, turbulent, steady, and the effects of buoyancy were taken into account. In addition, a full-scale chamber was also used in the experiment. The work revealed that numerical result was in good agreement with the experimental value of air flow rate, and other major findings were as the article.

    目錄 第一章 緒論 1-1 研究動機與目的 1-1 1-1-1 研究動機 1-1 1-1-2 研究目的 1-3 1-2 相關文獻回顧 1-4 1-3 研究內容與範圍 1-7 1-3-1 研究內容概要 1-7 1-3-2 研究範圍 1-8 1-4 研究架構與流程 1-9 第二章 研究方法 2-1 台灣地區空氣環境現況 2-1 2-1-1 建築外部空氣環境現況 2-1 2-1-2 自然通風策略 2-3 2-1-3 建築內部空氣環境現況 2-4 2-2 居室單元空間及變因之設定 2-6 2-2-1 居室單元空間及探討變因之選定 2-6 2-2-2 自然風條件設定 2-8 2-2-3 開窗模式與尺寸設定 2-8 2-2-4 水平導風百葉變因之設定 2-9 2-2-5 室內熱源之設定 2-11 2-3 通風效果評估指標之選定 2-12 2-3-1 換氣量之評估原則 2-13 2-3-2 風擊障礙不滿意度指標 2-15 第三章 水平導風百葉足尺實驗與數值模擬 3-1 水平導風百葉開口部自然通風之足尺實驗 3-1 3-1-1 足尺實驗體設定 3-1 3-1-2 實驗操作流程與實驗儀器系統 3-3 3-1-3 實驗結果分析 3-4 3-2 水平導風百葉開口部自然通風之數值模擬 3-7 3-2-1 計算流體力學於建築流場之應用 3-7 3-2-2 計算流體力學數學理論模式 3-9 3-2-3 水平導風百葉開口部之流場模擬 3-14 3-2-4 數值模擬結果分析 3-23 第四章 水平導風百葉開口部自然通風效果之探討 4-1 實驗與數值模擬結果比對 4-1 4-2 熱浮力對室內換氣量之影響 4-2 4-3 水平導風百葉自然通風之健康性檢討 4-3 4-3-1 水平導風百葉對室內換氣量之影響 4-4 4-3-2 入風風速、水平導風百葉深度與換氣增加率之關連性 4-6 4-3-2 入風風速、水平導風百葉深度與換氣量之關連性 4-7 4-4 水平導風百葉自然通風之舒適性檢討 4-9 4-4-1 水平導風百葉對室內溫度累積分佈之影響 4-9 4-4-2 水平導風百葉對睡眠區風擊現象之影響 4-10 4-5 小結 4-11 第五章 結論與建議 5-1 結論 5-1 5-2 後續研究建議 5-3 參考文獻

    一、中文文獻部分(依中文姓氏第一個字筆畫排序)
    C01 江哲銘,室內環境品質及性能研究—住宅室內環境品質性能基準研究,2002年10月。
    C02 江哲銘,邁向永續的健康建築,邁向21世紀永續建築環境國際研討會,2000。
    C03 江維華,開口部設計對室內流場之影響-以國民小學教室單元為例,台科大建築碩論(翁國陽教授指導),2001。
    C04 李建成等編,「泛亞熱帶地區建築設計與技術」,華南理工大學出版社,1998。
    C05 李彥頤,以中央橫軸旋轉窗探討自然通風狀態下通風效率之研究,成大建築碩論(江
    哲銘教授指導),1998.06。
    C06 周伯丞,建築軀殼開口部自然通風效果之研究,成大建研所博論(江哲銘教授指導),2000.6。
    C07 周伯丞,以生活行為模式為變因探討住宅室內空氣之研究,成大建築碩論(江哲銘教授指導),1994。
    C08 林沂品,網狀構材開口部對室內自然通風效果之影響,成大建築碩論(江哲銘教授指導),2001。
    C09 林憲德,建築節約能源設計規範與實例,營建雜誌社,2003。
    C10 林憲德,現代人類的居住環境,胡氏圖書,1994。
    C11 祐生研究基金會2002年度年報,祐生研究基金會,2002.04.14。
    C12 梁大慶,傾角式防風柵之防風效果研究,中興水土保持系博士論文(江永哲教授指導),2000。
    C13 徐偉森,住宅臥室空間自然通風效果之研究,成大建築碩論(江哲銘教授指導),1997.06。
    C14 陳念祖,高架地板置換式自然通風對室內通風效率之影響,成大建築碩論(江哲銘教授指導),2001。
    C15 陳錦賜,台灣綠建築發展機制之研究,邁向21世紀永續建築環境國際研討會, 2000。
    C16 曹君範,移動式流體化床焚化爐內熱流場之數值模擬,中原機械所碩士論文(鄧治東教授指導),2003.01。
    C17 張桂鳳,高齡者住居室內物理環境用後評估檢討,中原大學建築碩論(江哲銘教授指導),1994。
    C18 張勝凱,半導體廠災害應變模式之探討,台大機械所碩論(陳希立教授指導),2002.06.
    C19 黃建興,建築物開口部之研究—台灣都市地區集合住宅開口部設計原則擬議,成大建築碩論,1980.06。
    C20 賴榮平,台灣地區建築通風換氣問題探討,建築師雜誌,1980.04。
    C21 簡永和,住宅單元空間模擬自然通風換氣對室內空氣環境影響之研究,成功大學建築碩論(江哲銘教授指導),1995。
    C22 羅積玉,多元統計分析方法與應用,科技圖書股份有限公司,1990.05。
    C23 鍾朝嵩,相關與回歸分析,先鋒企業管理發展中心,1981。
    C24 魏嘉言,計算流力程式在無塵室空氣流場分析之應用,清華大學工科所碩論(施純寬教授指導),2001.06。
    二、英文文獻部分(依英文姓氏第一個字母排序)
    E01 American Society for Testing and Material(ASTM)E741-83.1990.”Standard test method for determining air leakage rate by tracer dilution”.
    E02 ASHRAE STANDARD 62-1999, Ventilation for Acceptable Indoor Air Quality,pp. 22
    E03 Athanassios A. Argiriou et al., Single-sided ventilation of building through shaded large openings, Energy 27 (2002) 93-115.
    E04 BSR/ASHRAE Standard 55P, pp. 33, 2002.
    E05 Baruch Givoni, Passive and Low Energy Cooling of Building, Van Nostrand Reinhold, 1994.
    E06 C.G. Speziale, T.B. Gatski, N. Fitzmaurice, An analysis of RNG-based turbulence models for homogeneous shear flow, Physics of Fluids 3(9)(1991)2278-2281.
    E07 E. Prianto , P. Depecker , Optimization of architectural design elements in tropical humid region with thermal comfort approach, Energy and Buildings 35 (2003) 273–280.
    E08 Etheridge, D & Sandberg, M., Building ventilation: Theory and Measurement, John Wiley & Sons, pp. 5-6, 1996.
    E09 E. Prianto , P. Depecker , Characteristic of airflow as the effect of balcony, opening design and inter division on indoor velocity – A case study of traditional dwelling in urban living quarter in tropical humid region, Energy and Buildings 34 (2002)401–409.
    E10 Guohui Gan, Effective depth of fresh air distribution in rooms with single-sided natural ventilation, Energy and Building, 31(2000)65-73.
    E11 H. B. AWBI, Energy Efficient Room Air Distribution, Renewable Energy 15, pp.293-299, 1998.
    E12 H. B. AWBI, Ventilation of Building, Van Nostrand Reinhold, 1991.
    E13 International Standard ISO 7730,Moderate Thermal Environments-Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort.
    E14 J. Phillips et al, M.E.Sc, P.Eng., Numerical Study of Convective and Radiative Heat Transfer from Window Glazing with a Venetian Blind, ASHARE Transaction: Symposia, 2001.
    E15 J.D. Posner, Measurement and prediction of indoor air flow in a model room, Energy and Building 35(2003)515-526.
    E16 Jia Qingxian, Zhao Rongyi,etc,「Features of Natural and Artificial Air Movement」,roomvent’2000,2000.
    E17 Laney R. Mills et al, The Benefit of Using Window Shades, ASHARE JOURNAL, 1993.
    E18 Linden, P.F., Fluid Mechanics of Natural Ventilation, “Annual Review of Fluid Mechanics”, 31, pp. 201-238, 1999.
    E19 Liddament, M. W., 1996, A Guide to Energy Efficient Ventilation, AIVC Guide.
    E20 Murakami, S, Overview of Turbulence Models Applied in CWE-1997, Journal of Wind Engineering and Industrial Aerodynamics 74-76, pp.1- 24, 1998.
    E21 Nelson R. M. and Pletcher R. H, An Explicit Scheme for the Calculation of Confined Turbulent Flow with Heat Transfer, Proc. 1974 Heat Transfer and Fluid Mechanics Institute, Standford University Press, Standford, California, 1974, pp. 154-170.
    E22 Norbert Lechner, Heating, Cooling, Lighting—Design Methed for Architects, John Wiley & Sons, Inc, 1991.
    E23 P. Ole Fanger,「Ventilation for buildings-Design criteria for the indoor environment」,CEN,1998.
    E24 P. Ole Fanger,「A New Chart Identifies the Percentage of Subjects Cissatisfied due to Craft as a Function of the Mean Air and the Air Temperature」,ASHRAE JOURNAL January,1987.
    E25 Peter V. Nielsen, CFD Models of Persons Evaluated by Full-Scalewind Channel Experiments, ROOMVENT ’96, Nagoya Japan, 1996.07.18.-07.20.
    E26 Peter, W. & Grieve, M., 1991, Measuring Ventilation Using Tracer-Gases, Brüel & Kjær.
    E27 Q. Chen, Comparison of Different k-e Models for Indoor Air Flow, Numerical Heat Transfer, Part B, 28:353- 369, 1995.
    E28 S Grignaffini and A Vallati, Experimental and Numerical Studies on Air Diffusion in a Single Office, Proceed: Indoor Air 2002, pp.311.
    E29 Shaw, C.Y.; Zhang, J.S. et al., 1993, Effect on Air Diffuser Layout on the Ventilation Conditions of a Workstation -- Part I: Air Distribution Patterns, “ASHRAE Transactions”, 99: 125-132.
    E30 Shaw, C.Y.; Zhang, J.S. et al., 1993, Effect on Air Diffuser Layout on the Ventilation Conditions of a Workstation -- Part II: Air-Exchange Efficiency and Ventilation Efficiency, “ASHRAE Transactions”, 99: 133-143.
    E31 T. Muneer, N. Abodahab, G Weir and J. Kubie, Windows in Building : Thermal, Acoustic, Visual and Solar Performance.
    E32 Thermal Environmental Conditions for Human Occupancy , BSR/ASHRAE Standard 55P, pp.4, 2002.11.
    E33 V. Yakhot, S.A. Orzag, Renormalization group analysis of turbulence. I. Basic theory, Journal of Scientific Computing 1(1986)3.
    E34 VICTOR OLGYAY, Design with Climate, Van Nostrand Reinhold, 1993.
    E35 Yi Jiang, Donald Alexander et al., Natural ventilation in buildings: measurement in a wind tunnel and numerical simulation with large-eddy simulation, Journal of Wind Engineering and Industrial Aerodynamics 91 (2003) 331–353.