| 研究生: |
羅亦荏 Luo, Yi-Ren |
|---|---|
| 論文名稱: |
主動脈磁振造影資料分析與研究 Aortic 4D flow MRI data analysis and investigation |
| 指導教授: |
藍永強
Lan, Yung-Chiang |
| 學位類別: |
碩士 Master |
| 系所名稱: |
理學院 - 光電科學與工程學系 Department of Photonics |
| 論文出版年: | 2018 |
| 畢業學年度: | 106 |
| 語文別: | 中文 |
| 論文頁數: | 49 |
| 中文關鍵詞: | 磁振造影 、相位對比 、三維影像重建 、壓力梯度 、壁面剪應力 |
| 外文關鍵詞: | MR image, Relative pressure distribution, Wall shear stress |
| 相關次數: | 點閱:119 下載:0 |
| 分享至: |
| 查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
本論文主要是利用成大醫院的飛利浦磁振造影系統提供數據資料,並利用MATLAB軟體進行數據的重組以及分析。
磁振造影系統能夠提供基本的切面流速資料,但是人體為一個三維的結構,所以重組過後的三維模型更能夠幫助醫生清楚的判斷。我們透過MATLAB所開發出的程式將原先多層切面的2維流速資料進行影像重組使之成為3維模型,再進行影像濾波、流速分析、壓力梯度分析與壁面剪應力分析等。
MR image has been further developed over the past few decades. With its nonradioactive and non-invasive it is widely used for disease detection. Nowadays we are enabled to obtain higher spatial resolution data. With higher quality data we allow a more thorough assessment of cardiovascular diseases. PC-MRI can provide three-dimensional velocity data at different times. Since these data contain complete space and time information we can quantitatively analysis on aorta. This study mainly uses MATLAB software for data processing and make a further analysis. In this study we will have investigation about relative pressure distribution and wall shear stress.
[1] Tal Geva, MD , “Magnetic Resonance Imaging: Historical Perspective, Journal of Cardiovascular Magnetic Resonance” , 573–580 (2006)
[2] Michael P Hartung, Thomas M Grist, Christopher J François , “Magnetic resonance angiography current status and future directions” , Journal of Cardiovascular Magnetic Resonance (2011)
[3] Wouter V. Potters & Henk A. Marquering & Ed VanBavel & Aart J. Nederveen , “Measuring Wall Shear Stress Using Velocity-Encoded MRI” , Curr Cardiovasc Imaging Rep (2014)
[4] 黃太煌“利用核磁共振光譜學探討蛋白質的結構動性及功能”物理雙月刊(廿四卷三期)P.403-P.412 (2001)
[5] Vijay P.B. Grover , Joshua M. Tognarelli , Mary M.E. Crossey , I. Jane Coxy, Simon D. Taylor-Robinson , Mark J.W. McPhail ,“Magnetic Resonance Imaging: Principles and Techniques: Lessons for Clinicians” , Journal Of Clinical And Experimental Hepatology (2015)
[6] Stuart Currie, Nigel Hoggard, Ian J Craven, Marios Hadjivassiliou, Iain D Wilkinson, “Understanding MRI basic MR physics for physicians” Postgraduate Medical Journal, P209–223 (2013)
[7] Joachim Lotz , MD , Christian Meier, PhD, Andreas Leppert , MD ,Michael Galanski , “Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation” Radio Graphics, P651–671 (2002)
[8] Zoran Stankovic, Bradley D. Allen, Julio Garcia, Kelly B. Jarvis, Michael Markl , “4D flow imaging with MRI”, Cardiovascular Diagnosis and Therapy, P173-192 (2014)
[9] Michael Markl, Alex Frydrychowicz, Sebastian Kozerke, Mike Hope, Oliver Wieben, “4D Flow MRI” , Journal Of Magnetic Resonance Imaging”, P1015–1036 (2012)
[10] Jelena Bock,1Alex Frydrychowicz, Ramona Lorenz, Daniel Hirtler, Alex J. Barker, Kevin M. Johnson, Raoul Arnold, Hans Burkhardt, Juergen Hennig, and Michael Markl, “In Vivo Noninvasive 4D Pressure Difference Mapping in the Human Aorta: Phantom Comparison and Application in Healthy Volunteers and Patients”, Magnetic Resonance in Medicine, P1079–1088 (2011)
[11] Adel M. Malek, Seth L. Alper, Seigo Izumo, “Hemodynamic shear stress and its role in atherosclerosis”, American Medical Association, P2035-2042 (1999)
[12] Sebastian B.S. Krittian, Pablo Lamata, Christian Michler, David A. Nordsletten, Jelena Bock, Chris P. Bradley, Alex Pitcher, Philip J. Kilner, Michael Markl, Nic P. Smith ,“A finite-element approach to the direct computation of relative cardiovascular pressure from time-resolved MR velocity data”, Medical Image Analysis (2012)
[13] J. Pfitzner,” Poiseuille and his law”, Anaesthesia, 1976, Volume 31, P.273-275
[14] Theodors G.Papaioannou, Christodoulos Stefanadis, “Vascular Wall Shear Stress: Basic Principles and Methods”, Hellenic Journal of Cardiology, P.9-15(2005)
[15] John D. Current, “Physics Related to Anesthesia Second Edition”, P.339-361
[16] Stephen A. Dyer and Justin S. Dyer, “Cubic-Spline Interpolation: Part 1”, IEEE Instrumentation and Measurement Magazine, P44-46 (2001)