本次研究以計算流體力學為工具,對T型管微混合器進行數值實驗,探討在T型管主流道內加入之橫條檔板對混合效率的影響,並以田口方法設計橫條擋板的結構參數,利用直交表搭配因子反應表找出對混合效率有利的參數趨勢,進而找出高混合效率之設計參數。
In this research numerial simulation of the flow field of T-tube micromixer are performed using a commercial CFD software. The effect of oblique crossbar structure on mixing efficiency of the micromixer.Taguchi method has been used to design the geometric parameter of the oblique crossbar. Using the orthogonal array and response table to find the advantage of mixing efficiency,then identify the geometric parameter with good mixing efficiency.
1-2
[1]Nguyen,N. and Wu,Z., “Micromixers-a review,” Journal of Micromechanics and Microengineering, NO.15 , pp1-16,2005
1-3
[2]Français, O., Jullien, M.C., Rousseau L., Poulichet, P., Desportes, S., Chouai , A., Lefevre, J.P., Delaire, J., “An Active Chaotic Micromixer Intergrating Thermal Actuation Associating PDMS and Silicon Microtechnology,” DTIP of MEMS & MOEMS Stresa, 26-28,April 2006
[3]Chung , Y.C., ”Order-Changing Microfluidic Mixer,” United State Patent, No.US6331073B1,2001
[4] Glasgow, I.,and Aubry, N., “Enhancement of microfluidic mixing using time pulsing,” Journal of Lab on a Chip , No. 3,pp.114-120,2003
[5] Tang, Z., Hong, S., Djukic, D.,Modi, V., West,A.C., Yardley, J.,and Osgood, R.M.,” Electrokinetic flow control for composition modulation in a Microchannel,” Journal of Micromechanics and microengineering,No. 12,pp.870-877,2008
[6] 郭勝欣, “浮力對T型管微混合器效率之影響,” 國立成功大學航空太空研究所論文,2010年
[7] Mülle, S.D., Mezi, I, Walther, J.H.,Koumoutsakos, P.,” Transverse momentum micromixer optimization with evolution strategies”, Computers & Fluids, No.33, pp521–531,2004
1-4
[8]Schwesinger, N., Frank, T., and Wurmus, H.,”A Modular micro-fluidic System with an Integrated Micromixer,”Journal of Micromechanics and Microengineering, Vol. 6,No. 1,pp. 99-102, 1996
[9] Friedhlem, S., and Steffen H., “Simulation of Helical Flows in Microchannels,” American Institute of Chemical Engineerings, Vol.50, No.4,pp.771-778,1996
[10] Virginie, M, Jacques, J., and Hubert, H.G., “Mixing Processes in a Zigzag Microchannel: Finite Element Simulations and Optical Study,” Analytical Chemistry, Vol. 74, No. 16,pp.4279-4286, 2002
[11]Stroock,A. D.,Dertinger, S. K.,Ajdar, A., Mezic, I., Stone, H.A. and Whitesides, G. M., “Chaotic Mixer for Microchannels,” Science,Vol.295,pp647-651,2002
[12] 周逸超 ,”以田口方法設計低雷諾數被動式T型管微混合器,” 國立成功大學航空太空研究所論文,2011年